When unplugging the cable, make sure not to bend the cable up and down, to not break of the Instrument connector. The USB-C (opens new window) port allows you to attach accessory equipment. The Micro-USB port allows the Instrument to be charged and when connected to a computer for data transfer. Make sure to only press the power button through the silicon covering. Wait for the Action Indicator to start flashing, to confirm the Instrument is booted up again. When the Instrument is running, hold the button for 5 seconds, to restart the instrument.A short push on the button will reset the instrument, in case a protocol crashes, etc.Wait for the Action Indicator to start flashing, to confirm the Instrument is on and booted up. Hold the button for at least 5 seconds to turn the Instrument on.The button in the back allows the instrument to be turned on as well as reset. Instrument is on, and battery is emptying. The Action Indicator has the following: Indicator Tubes can be attached in combination with a pump to provide a constant air flow and/or gas exchange. There are two sensors inside the clamp, one is close to the vents and the light guide while the second one is located on the other end of the clamp. The two vents allow air to be exchanged inside the Instrument. The leaf or material should not touch the the sensor, since it can alter the measured temperature reading. The sensor is inside a little groove and not flush with the clamp surface. When taking a measurement, make sure that the leaf is covering the IR sensor. The leaf temperature can be measured with the IR Contactless Temperature. Make sure it is clean and prevent it clamping hard rough materials which can cause scratches.ĭo not submerge in water, do not use solvents or detergents and do not use abrasive or rough cloths to clean the light guides. The Nitrile seal around the light guide on the main body and the clamp is ensuring the area measured is sealed from outside light. Make sure the PAR sensor is clean and not covered or shaded to prevent altering the actual intensity. When taking measurements, depending on the measurement protocol, the light intensity measured will be replicated inside the instrument. The PAR sensor is located on top of the instrument. In case the opening and closing feels rough, a small amount of lithium grease can be used to make the motion smoother. Push and release with an even motion to prevent it from snapping back. Push down the leaf clamp button to open the leaf clamp. # About MultispeQ v2.0 side and back view # Leaf Clamp Button Charging time depends on the power output of the power supply. Use a computer or standard USB power supply. Check Tutorials: Before Using Your Instrument Make Sure To Check Out The " Getting Started" Tutorials on how tho connect the Instrument and take the first Measurement.Software: Go to (opens new window) and download the Android app or the Desktop app.Turn On: Press and hold the power/reset button in the rear for 5 seconds.Once the instrument is fully charged, the light will turn off. When plugged in, the small green LED next to the micro-USB port lights up. Charging: Before using your MultispeQ, charge it for 8 hours using the supplied micro-USB cable*.
0 Comments
Leave a Reply. |